{"id":1459,"date":"2026-09-10T02:23:48","date_gmt":"2026-09-10T02:23:48","guid":{"rendered":"https:\/\/prennox.com\/?post_type=product&#038;p=1459"},"modified":"2026-09-22T07:25:23","modified_gmt":"2026-09-22T07:25:23","slug":"f-class-dmd","status":"publish","type":"product","link":"https:\/\/prennox.com\/ar\/product\/f-class-dmd\/","title":{"rendered":"F-\u0627\u0644\u0641\u0626\u0629 DMD"},"content":{"rendered":"<h2>F-\u0627\u0644\u0641\u0626\u0629 DMD<\/h2>\n<p>F-Class DMD is a three-layer flexible laminate consisting of polyester non-woven fabric, polyester film and polyester non-woven fabric, bonded together with an adhesive system.<br \/>\nIt is commonly supplied in Class B or Class F insulation grades for layer, phase, and liner insulation in dry-type transformers, motors, and other electrical equipment.<\/p>\n<p>&nbsp;<\/p>\n<h4>\u0627\u0644\u0645\u064a\u0632\u0627\u062a \u0627\u0644\u0631\u0626\u064a\u0633\u064a\u0629<\/h4>\n<ul>\n<li>Balanced dielectric barrier, flexibility and mechanical protection.<\/li>\n<li>Available in two commonly specified thermal grades.<\/li>\n<li>Can be supplied as rolls, sheets, slit tapes or converted parts.<\/li>\n<\/ul>\n<p>&nbsp;<\/p>\n<h4>\u0627\u0644\u062a\u0637\u0628\u064a\u0642\u0627\u062a<\/h4>\n<ul>\n<li>Layer and phase insulation in Class Fdry-type transformers<\/li>\n<li>Reactor and small transformer insulation<\/li>\n<li>Motor slot insulation and die-cut electrical parts<\/li>\n<\/ul>\n<p>&nbsp;<\/p>\n<h4>\u0627\u0644\u0628\u064a\u0627\u0646\u0627\u062a \u0627\u0644\u0641\u0646\u064a\u0629<\/h4>\n<div style=\"overflow-x: auto; width: 100%;\">\n<table style=\"width: 100%; border-collapse: collapse;\">\n<tbody>\n<tr>\n<td width=\"71\"><span style=\"color: #333333;\"><strong><b>\u0644\u0627.<\/b><\/strong><\/span><\/td>\n<td colspan=\"2\" width=\"318\"><span style=\"color: #333333;\"><strong><b>\u0645\u0639\u0644\u0645\u0629<\/b><\/strong><\/span><\/td>\n<td width=\"115\"><span style=\"color: #333333;\"><strong><b>\u0648\u062d\u062f\u0629<\/b><\/strong><\/span><\/td>\n<td colspan=\"5\" width=\"474\"><span style=\"color: #333333;\"><strong><b>\u062a\u062e\u0635\u064a\u0635<\/b><\/strong><\/span><\/td>\n<\/tr>\n<tr>\n<td width=\"71\">1<\/td>\n<td colspan=\"2\" width=\"318\">\u0633\u0645\u0643 \u0627\u0644\u0627\u0633\u0645\u064a<\/td>\n<td width=\"115\">\u0645\u0645<\/td>\n<td width=\"95\">0.15<\/td>\n<td width=\"94\">0.2<\/td>\n<td width=\"95\">0.25<\/td>\n<td width=\"94\">0.3<\/td>\n<td width=\"95\">0.35<\/td>\n<\/tr>\n<tr>\n<td rowspan=\"2\" width=\"71\">2<\/td>\n<td rowspan=\"2\" width=\"116\">\u0642\u0648\u0629 \u0627\u0644\u0634\u062f<\/td>\n<td width=\"201\">\u0642\u0628\u0644 \u0627\u0644\u0627\u0646\u062d\u0646\u0627\u0621 MD<\/td>\n<td width=\"115\">\u0646\/10 \u0645\u0644\u0645<\/td>\n<td width=\"95\">\u226580<\/td>\n<td width=\"94\">\u2265130<\/td>\n<td width=\"95\">\u2265190<\/td>\n<td width=\"94\">240<\/td>\n<td width=\"95\">280<\/td>\n<\/tr>\n<tr>\n<td width=\"201\">\u0642\u0628\u0644 \u062b\u0646\u064a \u0627\u0644\u0642\u0631\u0635 \u0627\u0644\u0645\u0636\u063a\u0648\u0637<\/td>\n<td width=\"115\">\u0646\/10 \u0645\u0644\u0645<\/td>\n<td width=\"95\">\u226580<\/td>\n<td width=\"94\">\u2265110<\/td>\n<td width=\"95\">\u2265170<\/td>\n<td width=\"94\">200<\/td>\n<td width=\"95\">250<\/td>\n<\/tr>\n<tr>\n<td rowspan=\"2\" width=\"71\">3<\/td>\n<td rowspan=\"2\" width=\"116\">\u0627\u0633\u062a\u0637\u0627\u0644\u0629<\/td>\n<td width=\"201\">\u0642\u0628\u0644 \u0627\u0644\u0627\u0646\u062d\u0646\u0627\u0621 MD<\/td>\n<td width=\"115\">%<\/td>\n<td colspan=\"3\" width=\"284\">\u226515<\/td>\n<td colspan=\"2\" width=\"189\">\u22655<\/td>\n<\/tr>\n<tr>\n<td width=\"201\">\u0642\u0628\u0644 \u062b\u0646\u064a \u0627\u0644\u0642\u0631\u0635 \u0627\u0644\u0645\u0636\u063a\u0648\u0637<\/td>\n<td width=\"115\">%<\/td>\n<td colspan=\"3\" width=\"284\">\u226520<\/td>\n<td colspan=\"2\" width=\"189\">\u22655<\/td>\n<\/tr>\n<tr>\n<td width=\"71\">4<\/td>\n<td width=\"116\">Breakdown voltage<\/td>\n<td width=\"201\">\u0642\u0628\u0644 \u0627\u0644\u0627\u0646\u062d\u0646\u0627\u0621<\/td>\n<td width=\"115\">\u0643\u064a\u0644\u0648 \u0641\u0648\u0644\u062a<\/td>\n<td width=\"95\">\u22656<\/td>\n<td width=\"94\">\u22658<\/td>\n<td width=\"95\">\u226510<\/td>\n<td width=\"94\">\u226514<\/td>\n<td width=\"95\">\u226516<\/td>\n<\/tr>\n<tr>\n<td width=\"71\">5<\/td>\n<td colspan=\"2\" width=\"318\">Temperature<\/td>\n<td width=\"115\">\u2103<\/td>\n<td colspan=\"5\" width=\"474\">\u2265155<\/td>\n<\/tr>\n<tr>\n<td colspan=\"9\" width=\"980\">Nominal thickness: \u00a00.15 mm, 0.18 mm, 0.20 mm, 0.25 mm, 0.30 mm, 0.35 mm, 0.38 mm<br \/>\nNominal width: 1000 mm<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p><span style=\"color: #333333;\"><strong><em><b><i>\u062a\u0623\u0643\u064a\u062f \u0627\u0644\u0645\u0648\u0627\u0635\u0641\u0627\u062a<\/i><\/b><\/em><\/strong><strong><em><b><i>\uff1a<\/i><\/b><\/em><\/strong><\/span><em><i>\u062a\u0645\u062b\u0644 \u0627\u0644\u0642\u064a\u0645 \u0627\u0644\u0645\u0648\u0636\u062d\u0629 \u0623\u0639\u0644\u0627\u0647 \u062e\u064a\u0627\u0631\u0627\u062a \u0627\u0644\u0633\u0648\u0642 \u0627\u0644\u0645\u0634\u062a\u0631\u0643\u0629. \u064a\u062a\u0645 \u062a\u0623\u0643\u064a\u062f \u0627\u0644\u0623\u0628\u0639\u0627\u062f \u0627\u0644\u0646\u0647\u0627\u0626\u064a\u0629 \u0648\u0627\u0644\u0641\u0626\u0629 \u0627\u0644\u062d\u0631\u0627\u0631\u064a\u0629 \u0648\u0645\u062a\u0637\u0644\u0628\u0627\u062a \u0627\u0644\u0623\u062f\u0627\u0621 \u0648\u0648\u062b\u0627\u0626\u0642 \u0627\u0644\u0641\u062d\u0635 \u0642\u0628\u0644 \u0627\u0644\u0637\u0644\u0628.<\/i><\/em><\/p>\n<\/div>","protected":false},"excerpt":{"rendered":"<p>F-Class DMD for layer, phase and liner insulation in dry-type transformers, motors, and other electrical equipment. F-Class DMD for layer, phase and liner insulation in dry-type transformers, motors, and other electrical equipment.<\/p>","protected":false},"featured_media":1460,"comment_status":"open","ping_status":"closed","template":"","meta":{"rank_math_title":"F-Class DMD Insulation Paper | Transformer and Motor Use","rank_math_description":"Source F-Class DMD for transformer and motor insulation in rolls, sheets or slit tapes. Send thickness, dimensions and quantity for a quote.","rank_math_canonical_url":"","rank_math_focus_keyword":"F-Class DMD"},"product_brand":[],"product_cat":[35],"product_tag":[],"class_list":["post-1459","product","type-product","status-publish","has-post-thumbnail","product_cat-electrical-insulation-materials","first","instock","shipping-taxable","product-type-simple"],"_links":{"self":[{"href":"https:\/\/prennox.com\/ar\/wp-json\/wp\/v2\/product\/1459","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/prennox.com\/ar\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/prennox.com\/ar\/wp-json\/wp\/v2\/types\/product"}],"replies":[{"embeddable":true,"href":"https:\/\/prennox.com\/ar\/wp-json\/wp\/v2\/comments?post=1459"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/prennox.com\/ar\/wp-json\/wp\/v2\/media\/1460"}],"wp:attachment":[{"href":"https:\/\/prennox.com\/ar\/wp-json\/wp\/v2\/media?parent=1459"}],"wp:term":[{"taxonomy":"product_brand","embeddable":true,"href":"https:\/\/prennox.com\/ar\/wp-json\/wp\/v2\/product_brand?post=1459"},{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/prennox.com\/ar\/wp-json\/wp\/v2\/product_cat?post=1459"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/prennox.com\/ar\/wp-json\/wp\/v2\/product_tag?post=1459"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}