{"id":1434,"date":"2026-09-10T01:20:34","date_gmt":"2026-09-10T01:20:34","guid":{"rendered":"https:\/\/prennox.com\/?post_type=product&#038;p=1434"},"modified":"2026-09-10T01:20:34","modified_gmt":"2026-09-10T01:20:34","slug":"hi-b-high-permeability-crgo-electrical-steel-coil","status":"publish","type":"product","link":"https:\/\/prennox.com\/pt\/produto\/hi-b-high-permeability-crgo-electrical-steel-coil\/","title":{"rendered":"Hi-B High-Permeability CRGO Electrical Steel Coil"},"content":{"rendered":"<p>High-permeability grain-oriented electrical steel, also described as high-permeability GOES or HGO, provides higher magnetic polarization and lower core loss than conventional grain-oriented grades. In some markets, this material class is also referred to as Hi-B-type CRGO.<\/p>\n<p>It is used in transformer core designs where lower no-load loss, higher flux density or improved material efficiency is required. Final material selection should be based on the transformer design, target magnetic properties and downstream core-processing method.<\/p>\n<p>&nbsp;<\/p>\n<h4>Key Features<\/h4>\n<ul>\n<li>Higher magnetic polarization than conventional GOES<\/li>\n<li>Lower material core loss for low-no-load-loss transformer designs<\/li>\n<li>Available in multiple thicknesses and performance classes<\/li>\n<li>Full-coil and slit-strip supply available according to confirmed requirements<\/li>\n<\/ul>\n<p>&nbsp;<\/p>\n<h4>Quick Specifications<\/h4>\n<div style=\"overflow-x: auto; width: 100%;\">\n<table style=\"width: 100%; border-collapse: collapse;\">\n<tbody>\n<tr>\n<td><span style=\"color: #333333;\"><strong>Par\u00e2metro<\/strong><\/span><\/td>\n<td><span style=\"color: #333333;\"><strong>Available Specification<\/strong><\/span><\/td>\n<\/tr>\n<tr>\n<td>Product Type<\/td>\n<td>High-permeability grain-oriented electrical steel<\/td>\n<\/tr>\n<tr>\n<td>Common Market Terms<\/td>\n<td>High-permeability GOES, HGO, high-permeability CRGO, Hi-B-type material<\/td>\n<\/tr>\n<tr>\n<td>Domain Refinement<\/td>\n<td>Non-domain-refined<\/td>\n<\/tr>\n<tr>\n<td>Nominal Thickness<\/td>\n<td>0.23 \/ 0.27 \/ 0.30 mm<\/td>\n<\/tr>\n<tr>\n<td>Standard Coil Width<\/td>\n<td>800\u20131000 mm<\/td>\n<\/tr>\n<tr>\n<td>Coil Inner Diameter<\/td>\n<td>510 mm<\/td>\n<\/tr>\n<tr>\n<td>Typical Coil Weight<\/td>\n<td>3\u20135 metric tons per coil<\/td>\n<\/tr>\n<tr>\n<td>Delivery Form<\/td>\n<td>Full coil \/ slit coil \/ slit strip<\/td>\n<\/tr>\n<tr>\n<td>Material Specification<\/td>\n<td>GB\/T 2521.2-2025 or another agreed material specification<\/td>\n<\/tr>\n<tr>\n<td>Magnetic Properties<\/td>\n<td>According to the confirmed grade, test method and inspection certificate<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<h4>Typical Applications<\/h4>\n<ul>\n<li>Energy-efficient distribution transformer cores<\/li>\n<li>Power transformer cores<\/li>\n<li>Low-no-load-loss transformer designs<\/li>\n<li>Laminated or wound cores, subject to grade and process confirmation<\/li>\n<\/ul>\n<p>&nbsp;<\/p>\n<h4>Material Selection and Quality Confirmation<\/h4>\n<p>Higher material performance does not by itself guarantee the no-load loss of a finished transformer. Core design, joint configuration, cutting quality, burr control, assembly and processing stresses also affect final core performance.<\/p>\n<p>The required material grade and test conditions should therefore be confirmed against the transformer design before supply.<\/p>\n<p>&nbsp;<\/p>\n<h4>Information Required for Quotation<\/h4>\n<p>Please provide:<\/p>\n<ul>\n<li>Required grade, equivalent grade or target core-loss class<\/li>\n<li>Required magnetic polarization and test conditions<\/li>\n<li>Thickness and coil or slit width<\/li>\n<li>Coil inner diameter and preferred coil weight<\/li>\n<li>Quantity, destination and packing requirements<\/li>\n<li>Required inspection certificate or material documentation<\/li>\n<\/ul>\n<p>&nbsp;<\/p>\n<h4>RFQ<\/h4>\n<p><strong>Send your required grade or target magnetic properties, thickness, width, quantity and destination for technical confirmation and quotation.<\/strong><\/p>\n<\/div>","protected":false},"excerpt":{"rendered":"<p>High-permeability grain-oriented electrical steel, also described as high-permeability GOES or HGO, provides higher magnetic polarization and lower core loss than conventional grain-oriented grades. In some markets, this material class is also referred to as Hi-B-type CRGO.<\/p>","protected":false},"featured_media":1435,"comment_status":"open","ping_status":"closed","template":"","meta":[],"product_brand":[],"product_cat":[34],"product_tag":[],"class_list":["post-1434","product","type-product","status-publish","has-post-thumbnail","product_cat-crgo-silicon-steel","first","instock","shipping-taxable","product-type-simple"],"_links":{"self":[{"href":"https:\/\/prennox.com\/pt\/wp-json\/wp\/v2\/product\/1434","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/prennox.com\/pt\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/prennox.com\/pt\/wp-json\/wp\/v2\/types\/product"}],"replies":[{"embeddable":true,"href":"https:\/\/prennox.com\/pt\/wp-json\/wp\/v2\/comments?post=1434"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/prennox.com\/pt\/wp-json\/wp\/v2\/media\/1435"}],"wp:attachment":[{"href":"https:\/\/prennox.com\/pt\/wp-json\/wp\/v2\/media?parent=1434"}],"wp:term":[{"taxonomy":"product_brand","embeddable":true,"href":"https:\/\/prennox.com\/pt\/wp-json\/wp\/v2\/product_brand?post=1434"},{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/prennox.com\/pt\/wp-json\/wp\/v2\/product_cat?post=1434"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/prennox.com\/pt\/wp-json\/wp\/v2\/product_tag?post=1434"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}