Cast Resin Dry-Type Distribution Transformer

产品页表单

Cast Resin Dry-Type Distribution Transformer

A three-phase cast resin transformer for indoor power distribution in commercial buildings, industrial facilities and infrastructure projects. The cast resin coil system provides electrical insulation and mechanical strength. Its oil-free construction is suitable for installations where fire risk, maintenance, ventilation and indoor operating conditions must be considered.

Product Overview

A three-phase cast resin transformer for indoor power distribution in commercial buildings, industrial facilities and infrastructure projects.
The cast resin coil system provides electrical insulation and mechanical strength. Its oil-free construction is suitable for installations where fire risk, maintenance, ventilation and indoor operating conditions must be considered.
Natural-air cooling is standard for applicable designs, while forced-air cooling and temperature-control functions can be provided where required.

 

Key Features

  • Cast resin coil system designed for electrical insulation and mechanical strength.
  • Controlled resin mixing and vacuum-casting processes.
  • Grain-oriented electrical steel core designed to meet the confirmed loss and sound-level requirements.
  • H-class insulation materials available for the documented product series.
  • Natural-air cooling with optional forced-air cooling.
  • Optional temperature display, fan control, alarm and trip functions.
  • Open construction or protective enclosure available according to the installation environment.

 

Reference Specifications

ParameterAvailable Configuration
TypeThree-phase cast resin dry-type transformer
Core materialGrain-oriented electrical steel
Reference capacity range30–2500kVA for the documented 10kV series
Rated voltageSpecified for each project
FrequencyProject-specified
GB seriesSCB12 / SCB14 / SCB18, where applicable
Guaranteed lossesConfirmed in the approved technical data sheet
Vector groupDyn11 or project-specified
Cooling methodAN; AF available with cooling fans
Insulation systemAccording to the confirmed thermal and temperature-rise requirements
Voltage regulationOff-circuit tapping
Tapping rangeProject-specific
Short-circuit impedanceAccording to rated capacity and approved design
EnclosureOpen indoor type or specified protective enclosure
Enclosure ratingConfirmed for the installation environment
MonitoringTemperature display, fan control, alarm and trip functions available

Standards and Testing

Chinese-market configurations can be reviewed against the applicable requirements of GB 1094, GB/T 10228 and GB 20052.

Export configurations can be designed and tested to IEC 60076-11 or another specified project standard. Final compliance depends on the approved design, guaranteed values and agreed test documentation.

 

Routine tests may include:

  • Winding resistance
  • Voltage ratio and vector group
  • No-load loss and no-load current
  • Load loss and short-circuit impedance
  • Routine dielectric tests
  • Partial-discharge measurement, where applicable

Temperature-rise testing, sound-level measurement, environmental tests, fire-behaviour tests and third-party inspection can be agreed when required.

 

التطبيقات

  • Commercial buildings
  • Industrial facilities
  • Indoor distribution substations
  • Residential developments
  • Data centers
  • Hospitals, schools and public facilities
  • Installations where oil-free transformer construction is preferred

 

Request a Quotation