A three-phase cast resin transformer for indoor power distribution in commercial buildings, industrial facilities and infrastructure projects. The cast resin coil system provides electrical insulation and mechanical strength. Its oil-free construction is suitable for installations where fire risk, maintenance, ventilation and indoor operating conditions must be considered.
A three-phase cast resin transformer for indoor power distribution in commercial buildings, industrial facilities and infrastructure projects.
The cast resin coil system provides electrical insulation and mechanical strength. Its oil-free construction is suitable for installations where fire risk, maintenance, ventilation and indoor operating conditions must be considered.
Natural-air cooling is standard for applicable designs, while forced-air cooling and temperature-control functions can be provided where required.
| Parameter | Available Configuration |
| Type | Three-phase cast resin dry-type transformer |
| Core material | Grain-oriented electrical steel |
| Reference capacity range | 30–2500kVA for the documented 10kV series |
| Rated voltage | Specified for each project |
| Frequency | Project-specified |
| GB series | SCB12 / SCB14 / SCB18, where applicable |
| Guaranteed losses | Confirmed in the approved technical data sheet |
| Vector group | Dyn11 or project-specified |
| Cooling method | AN; AF available with cooling fans |
| Insulation system | According to the confirmed thermal and temperature-rise requirements |
| Voltage regulation | Off-circuit tapping |
| Tapping range | Project-specific |
| Short-circuit impedance | According to rated capacity and approved design |
| Enclosure | Open indoor type or specified protective enclosure |
| Enclosure rating | Confirmed for the installation environment |
| Monitoring | Temperature display, fan control, alarm and trip functions available |
Chinese-market configurations can be reviewed against the applicable requirements of GB 1094, GB/T 10228 and GB 20052.
Export configurations can be designed and tested to IEC 60076-11 or another specified project standard. Final compliance depends on the approved design, guaranteed values and agreed test documentation.
Routine tests may include:
Temperature-rise testing, sound-level measurement, environmental tests, fire-behaviour tests and third-party inspection can be agreed when required.
Please provide the rated capacity, voltage ratio, frequency, vector group, tapping range, guaranteed loss requirements, cooling method, enclosure requirements, site conditions, applicable standard, quantity and destination.