Cast Resin Dry-Type Distribution Transformer

A three-phase cast resin transformer for indoor power distribution in commercial buildings, industrial facilities and infrastructure projects. The cast resin coil system provides electrical insulation and mechanical strength. Its oil-free construction is suitable for installations where fire risk, maintenance, ventilation and indoor operating conditions must be considered.

Descripción general del producto

A three-phase cast resin transformer for indoor power distribution in commercial buildings, industrial facilities and infrastructure projects.
The cast resin coil system provides electrical insulation and mechanical strength. Its oil-free construction is suitable for installations where fire risk, maintenance, ventilation and indoor operating conditions must be considered.
Natural-air cooling is standard for applicable designs, while forced-air cooling and temperature-control functions can be provided where required.

 

Características clave

  • Cast resin coil system designed for electrical insulation and mechanical strength.
  • Controlled resin mixing and vacuum-casting processes.
  • Grain-oriented electrical steel core designed to meet the confirmed loss and sound-level requirements.
  • H-class insulation materials available for the documented product series.
  • Natural-air cooling with optional forced-air cooling.
  • Optional temperature display, fan control, alarm and trip functions.
  • Open construction or protective enclosure available according to the installation environment.

 

Especificaciones de referencia

ParámetroConfiguración disponible
TipoThree-phase cast resin dry-type transformer
Material centralAcero eléctrico orientado a granos
Rango de capacidad de referencia30–2500kVA for the documented 10kV series
Tensión nominalEspecificado para cada proyecto
FrecuenciaProyecto especificado
Serie GBSCB12 / SCB14 / SCB18, where applicable
Pérdidas garantizadasConfirmado en la ficha técnica aprobada
Grupo vectorialDyn11 or project-specified
Método de enfriamientoAN; AF available with cooling fans
Insulation systemAccording to the confirmed thermal and temperature-rise requirements
Regulación de voltajeTocado fuera de circuito
Rango de golpecitosEspecífico del proyecto
Short-circuit impedanceAccording to rated capacity and approved design
EnclosureOpen indoor type or specified protective enclosure
Enclosure ratingConfirmed for the installation environment
MonitoringTemperature display, fan control, alarm and trip functions available

Estándares y pruebas

Chinese-market configurations can be reviewed against the applicable requirements of GB 1094, GB/T 10228 and GB 20052.

Export configurations can be designed and tested to IEC 60076-11 or another specified project standard. Final compliance depends on the approved design, guaranteed values and agreed test documentation.

 

Las pruebas de rutina pueden incluir:

  • Resistencia al bobinado
  • Relación de tensión y grupo de vectores
  • Pérdida sin carga y corriente sin carga
  • Pérdida de carga e impedancia de cortocircuito
  • Pruebas dieléctricas de rutina
  • Partial-discharge measurement, where applicable

Temperature-rise testing, sound-level measurement, environmental tests, fire-behaviour tests and third-party inspection can be agreed when required.

 

Aplicaciones

  • Commercial buildings
  • Industrial facilities
  • Indoor distribution substations
  • Residential developments
  • Data centers
  • Hospitals, schools and public facilities
  • Installations where oil-free transformer construction is preferred

 

Solicite una cotización

Please provide the rated capacity, voltage ratio, frequency, vector group, tapping range, guaranteed loss requirements, cooling method, enclosure requirements, site conditions, applicable standard, quantity and destination.